Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: Tasmota
Plugin: tasmota
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Single switch (Sonoff Basic, RF, Touch...) | gateway | — | Manual | 3 |
| Dual switch (Sonoff Dual, T1 2CH...) | gateway | — | Manual | 4 |
| 3 channel switch (Sonoff 3CH, Tuya 3CH...) | gateway | — | Manual | 5 |
| 4 channel switch (Sonoff 4CH, T1 4CH...) | gateway | — | Manual | 6 |
| Dimmer (Sonoff D1...) | dimmablelight | — | Manual | 4 |
| Tasmota power switch | powerswitch | — | Automatic | 3 |
| Tasmota light | light | — | Automatic | 3 |
| Tasmota shutter | shutter, closable | — | Automatic | 2 |
| Tasmota blinds | blind, closable | — | Automatic | 2 |
| Power meter | Consumption meter | — | Automatic | 4 |
Per-model detail¶
Single switch (Sonoff Basic, RF, Touch...) — sonoff_basic
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
ipAddress |
IP address | QString | — | — | no |
attachedDeviceCH1 |
Connected device | QString | — | None |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
power |
Power | bool | — |
Dual switch (Sonoff Dual, T1 2CH...) — sonoff_dual
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
ipAddress |
IP address | QString | — | — | no |
attachedDeviceCH1 |
Connected device 1 | QString | — | None |
no |
attachedDeviceCH2 |
Connected device 2 | QString | — | None |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
powerCH1 |
Power channel 1 | bool | — |
powerCH2 |
Power channel 2 | bool | — |
3 channel switch (Sonoff 3CH, Tuya 3CH...) — sonoff_tri
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
ipAddress |
IP address | QString | — | — | no |
attachedDeviceCH1 |
Connected device 1 | QString | — | None |
no |
attachedDeviceCH2 |
Connected device 2 | QString | — | None |
no |
attachedDeviceCH3 |
Connected device 3 | QString | — | None |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
powerCH1 |
Power channel 1 | bool | — |
powerCH2 |
Power channel 2 | bool | — |
powerCH3 |
Power channel 3 | bool | — |
4 channel switch (Sonoff 4CH, T1 4CH...) — sonoff_quad
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
ipAddress |
IP address | QString | — | — | no |
attachedDeviceCH1 |
Connected device 1 | QString | — | None |
no |
attachedDeviceCH2 |
Connected device 2 | QString | — | None |
no |
attachedDeviceCH3 |
Connected device 3 | QString | — | None |
no |
attachedDeviceCH4 |
Connected device 4 | QString | — | None |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
powerCH1 |
Power channel 1 | bool | — |
powerCH2 |
Power channel 2 | bool | — |
powerCH3 |
Power channel 3 | bool | — |
powerCH4 |
Power channel 4 | bool | — |
Dimmer (Sonoff D1...) — sonoff_dimmer
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
ipAddress |
IP address | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
power |
Power | bool | — |
brightness |
Brightness | int | — |
Tasmota power switch — tasmotaSwitch
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
channelName |
Channel name | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
power |
Power | bool | — |
Tasmota light — tasmotaLight
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
channelName |
Channel name | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
power |
Power | bool | — |
Tasmota shutter — tasmotaShutter
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
openingChannel |
Opening channel | QString | — | — | no |
closingChannel |
Closing channel | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
Tasmota blinds — tasmotaBlinds
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
openingChannel |
Opening channel | QString | — | — | no |
closingChannel |
Closing channel | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
Power meter — powerMeterChannel
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
channelName |
Channel name | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
signalStrength |
Signal strength | uint | Percentage |
currentPower |
Current power consumption | double | Watt |
totalEnergyConsumed |
Total consumed energy | double | KiloWattHour |