ABB Terra AC charging station

TESTING ETM

Connection: LOCAL

Connect ABB Terra AC chargers over Modbus TCP or Modbus RTU.

The ABB Terra AC charging station comes in two communication variants: Modbus TCP (Ethernet/LAN) and Modbus RTU (RS485 bus).

1. Choosing the variant

  • TCP: the station sits on the local network, addressed by its IP address or hostname. Added by network discovery.
  • RTU: the station sits on an RS485 bus, addressed by its slave address.

2. Wiring

  • TCP: an Ethernet cable into the hub's network.
  • RTU: A↔A, B↔B, ground, 120 Ω termination.

3. Adding in PowerSync

TCP variant: automatic discovery on the network, or manual addition (IP, port). RTU variant: added through the RTU master plus the slave address. See Adding a device.

4. Verification

connected, pluggedIn and then charging reflect the state of the session; maxChargingCurrent reflects the current setpoint.


Reference

Application labels

The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.

Manufacturer: ABB
Plugin: AbbTerra

Supported models

Model Role Transport Pairing Quantities
Terra AC Charger (TCP) EV charger Modbus TCP Auto-discovery / Manual 17
Terra AC Charger (RTU) EV charger Modbus RTU Auto-discovery / Manual 17

Per-model detail

Terra AC Charger (TCP) — terraAcTcp

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no
port Port uint — 502 no
slaveId Slave ID uint 1–255 1 no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
charging Charging bool —
power Charging enabled bool —
maxChargingCurrent Maximum charging current double Ampere
phaseCount Phase count uint —
currentPower Active power double Watt
currentPhase1 Current phase 1 double Ampere
currentPhase2 Current phase 2 double Ampere
currentPhase3 Current phase 3 double Ampere
voltagePhase1 Voltage phase 1 double Volt
voltagePhase2 Voltage phase 2 double Volt
voltagePhase3 Voltage phase 3 double Volt
sessionEnergy Session energy double KiloWattHour
firmwareVersion Firmware version QString —
serialNumber Serial number QString —
errorCode Error code uint —
Terra AC Charger (RTU) — terraAcRtu

Settings:

Key Label Type Range Default Read-only
rtuMaster Modbus RTU master QString — — no
slaveId Modbus slave ID uint 1–247 1 no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
charging Charging bool —
power Charging enabled bool —
maxChargingCurrent Maximum charging current double Ampere
phaseCount Phase count uint —
currentPower Active power double Watt
currentPhase1 Current phase 1 double Ampere
currentPhase2 Current phase 2 double Ampere
currentPhase3 Current phase 3 double Ampere
voltagePhase1 Voltage phase 1 double Volt
voltagePhase2 Voltage phase 2 double Volt
voltagePhase3 Voltage phase 3 double Volt
sessionEnergy Session energy double KiloWattHour
firmwareVersion Firmware version QString —
serialNumber Serial number QString —
errorCode Error code uint —