ABB Terra AC charging station¶
TESTING ETM
Connection: LOCAL
Connect ABB Terra AC chargers over Modbus TCP or Modbus RTU.
The ABB Terra AC charging station comes in two communication variants: Modbus TCP (Ethernet/LAN) and Modbus RTU (RS485 bus).
1. Choosing the variant¶
- TCP: the station sits on the local network, addressed by its IP address or hostname. Added by network discovery.
- RTU: the station sits on an RS485 bus, addressed by its slave address.
2. Wiring¶
- TCP: an Ethernet cable into the hub's network.
- RTU: A↔A, B↔B, ground, 120 Ω termination.
3. Adding in PowerSync¶
TCP variant: automatic discovery on the network, or manual addition (IP, port). RTU variant: added through the RTU master plus the slave address. See Adding a device.
4. Verification¶
connected, pluggedIn and then charging reflect the state of the session;
maxChargingCurrent reflects the current setpoint.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: ABB
Plugin: AbbTerra
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Terra AC Charger (TCP) | EV charger | Modbus TCP | Auto-discovery / Manual | 17 |
| Terra AC Charger (RTU) | EV charger | Modbus RTU | Auto-discovery / Manual | 17 |
Per-model detail¶
Terra AC Charger (TCP) — terraAcTcp
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
macAddress |
MAC address | QString | — | — | yes |
address |
Host address | QString | — | — | no |
hostName |
Host name | QString | — | — | no |
port |
Port | uint | — | 502 |
no |
slaveId |
Slave ID | uint | 1–255 | 1 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
pluggedIn |
Plugged in | bool | — |
charging |
Charging | bool | — |
power |
Charging enabled | bool | — |
maxChargingCurrent |
Maximum charging current | double | Ampere |
phaseCount |
Phase count | uint | — |
currentPower |
Active power | double | Watt |
currentPhase1 |
Current phase 1 | double | Ampere |
currentPhase2 |
Current phase 2 | double | Ampere |
currentPhase3 |
Current phase 3 | double | Ampere |
voltagePhase1 |
Voltage phase 1 | double | Volt |
voltagePhase2 |
Voltage phase 2 | double | Volt |
voltagePhase3 |
Voltage phase 3 | double | Volt |
sessionEnergy |
Session energy | double | KiloWattHour |
firmwareVersion |
Firmware version | QString | — |
serialNumber |
Serial number | QString | — |
errorCode |
Error code | uint | — |
Terra AC Charger (RTU) — terraAcRtu
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
rtuMaster |
Modbus RTU master | QString | — | — | no |
slaveId |
Modbus slave ID | uint | 1–247 | 1 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
pluggedIn |
Plugged in | bool | — |
charging |
Charging | bool | — |
power |
Charging enabled | bool | — |
maxChargingCurrent |
Maximum charging current | double | Ampere |
phaseCount |
Phase count | uint | — |
currentPower |
Active power | double | Watt |
currentPhase1 |
Current phase 1 | double | Ampere |
currentPhase2 |
Current phase 2 | double | Ampere |
currentPhase3 |
Current phase 3 | double | Ampere |
voltagePhase1 |
Voltage phase 1 | double | Volt |
voltagePhase2 |
Voltage phase 2 | double | Volt |
voltagePhase3 |
Voltage phase 3 | double | Volt |
sessionEnergy |
Session energy | double | KiloWattHour |
firmwareVersion |
Firmware version | QString | — |
serialNumber |
Serial number | QString | — |
errorCode |
Error code | uint | — |