MENNEKES¶
STABLE NYMEA CONSUMER
Connection: LOCAL
Connect MENNEKES wallboxes to nymea.
Installation guide coming soon.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: MENNEKES
Plugin: Mennekes
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| AMTRON Charge Control/Professional | evchargerac, Consumption meter | Modbus TCP | Auto-discovery / Manual | 10 |
| AMTRON XTRA/Premium | evchargerac, Consumption meter | Modbus TCP | Auto-discovery / Manual | 9 |
| AMTRON Compact 2.0s | evchargerac, Consumption meter | Modbus RTU | Auto-discovery / Manual | 12 |
Per-model detail¶
AMTRON Charge Control/Professional — amtronECU
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
address |
Host address | QString | — | — | no |
hostName |
Host name | QString | — | — | no |
macAddress |
MAC address | QString | — | — | yes |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
pluggedIn |
Plugged in | bool | — |
charging |
Charging | bool | — |
phaseCount |
Connected phases | uint | — |
currentPower |
Active power | double | Watt |
totalEnergyConsumed |
Total consumed energy | double | KiloWattHour |
power |
Charging enabled | bool | — |
maxChargingCurrent |
Maximum charging current | double | Ampere |
sessionEnergy |
Session energy | double | KiloWattHour |
firmwareVersion |
Firmware version | QString | — |
AMTRON XTRA/Premium — amtronHCC3
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
address |
Host address | QString | — | — | no |
hostName |
Host name | QString | — | — | no |
macAddress |
MAC address | QString | — | — | yes |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
pluggedIn |
Plugged in | bool | — |
charging |
Charging | bool | — |
phaseCount |
Connected phases | uint | — |
currentPower |
Active power | double | Watt |
totalEnergyConsumed |
Total consumed energy | double | KiloWattHour |
sessionEnergy |
Session energy | double | KiloWattHour |
power |
Charging enabled | bool | — |
maxChargingCurrent |
Maximum charging current | double | Ampere |
AMTRON Compact 2.0s — amtronCompact20
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
slaveAddress |
Modbus slave address | uint | — | 1 |
no |
modbusMasterUuid |
Modbus RTU master | QUuid | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
currentVersion |
Firmware version | QString | — |
pluggedIn |
Plugged in | bool | — |
charging |
Charging | bool | — |
phaseCount |
Charging phases | uint | — |
desiredPhaseCount |
Desired phase count | uint | — |
currentPower |
Active power | double | Watt |
totalEnergyConsumed |
Total consumed energy | double | KiloWattHour |
power |
Charging enabled | bool | — |
maxChargingCurrent |
Maximum charging current | double | Ampere |
sessionEnergy |
Session energy | double | KiloWattHour |
solarChargingMode |
Solar charging mode | QString | — |