Modbus Commander¶
STABLE NYMEA COMMUNITY
Connection: LOCAL
Write and read Modbus register.
Installation guide coming soon.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: nymea
Plugin: ModbusCommander
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Modbus TCP client | — | Modbus TCP | Manual / Auto-discovery | 1 |
| Modbus RTU client | — | Modbus RTU | Auto-discovery | 1 |
| Coil | — | — | Auto-discovery | 2 |
| Discrete input | — | — | Auto-discovery | 2 |
| Input register | — | — | Auto-discovery | 2 |
| Holding register | — | — | Auto-discovery | 2 |
Per-model detail¶
Modbus TCP client — modbusTCPClient
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
ipAddress |
IP Address | QString | — | 127.0.0.1 |
no |
port |
Port | uint | — | 502 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
Modbus RTU client — modbusRTUClient
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
modbusMasterUuid |
Modbus RTU master | QUuid | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
Coil — coil
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
slaveAddress |
Slave address | uint | — | 1 |
no |
registerAddress |
Register address | uint | — | 0 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
value |
Value | bool | — |
Discrete input — discreteInput
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
slaveAddress |
Slave address | uint | — | 1 |
no |
registerAddress |
Register address | uint | — | 0 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
value |
Value | bool | — |
Input register — inputRegister
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
slaveAddress |
Slave address | uint | — | 1 |
no |
registerAddress |
Register address | uint | — | 0 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
value |
Value | int | — |
Holding register — holdingRegister
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
slaveAddress |
Slave address | uint | — | 1 |
no |
registerAddress |
Register address | uint | — | 0 |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
value |
Value | uint | — |