Sungrow Inverter¶
STABLE NYMEA CONSUMER
Connection: LOCAL
Connect to Sungrow inverters.
Installation guide coming soon.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: Sungrow
Plugin: Sungrow
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Sungrow Inverter | solarinverter | Modbus TCP | Auto-discovery | 5 |
| Sungrow Meter | Energy meter | — | Automatic | 14 |
| Sungrow Battery | energystorage | — | Automatic | 8 |
Per-model detail¶
Sungrow Inverter — sungrowInverterTcp
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
address |
Host address | QString | — | — | no |
hostName |
Host name | QString | — | — | no |
macAddress |
MAC address | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
currentPower |
Active power | double | Watt |
totalEnergyProduced |
Total energy produced | double | KiloWattHour |
temperature |
Temperature | double | DegreeCelsius |
frequency |
Frequency | double | Hertz |
Sungrow Meter — sungrowMeter
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
currentPower |
Current power | double | Watt |
voltagePhaseA |
Voltage phase A | double | Volt |
voltagePhaseB |
Voltage phase B | double | Volt |
voltagePhaseC |
Voltage phase C | double | Volt |
currentPhaseA |
Current phase A | double | Ampere |
currentPhaseB |
Current phase B | double | Ampere |
currentPhaseC |
Current phase C | double | Ampere |
apparentPowerPhaseA |
Apparent power phase A | double | VoltAmpere |
apparentPowerPhaseB |
Apparent power phase B | double | VoltAmpere |
apparentPowerPhaseC |
Apparent power phase C | double | VoltAmpere |
totalEnergyProduced |
Total returned energy | double | KiloWattHour |
totalEnergyConsumed |
Total imported energy | double | KiloWattHour |
frequency |
Frequency | double | Hertz |
Sungrow Battery — sungrowBattery
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
batteryCritical |
Battery critical | bool | — |
batteryLevel |
Battery level | int | Percentage |
currentPower |
Total real power | double | Watt |
voltage |
Voltage | double | Volt |
temperature |
Temperature | double | DegreeCelsius |
capacity |
Capacity | double | KiloWattHour |
chargingState |
Charging state | QString | — |