EDF¶
STABLE ETM CONSUMER
Connection: LOCAL — No network connection: prices are computed on the box from the contract entered.
Prices of the EDF electricity contract (Base, peak / off-peak hours, EJP), computed on the box.
The EDF plugin describes an EDF electricity contract on the Tarif Bleu (France; Base, peak / off-peak hours, or EJP option) and publishes, for the engine, the price of the period in progress and the price slots up to the end of the next day. Chosen as the Tariff source, it replaces the entered tariff. Everything is computed on the box: the plugin opens no network connection.
Package: powersync-plugin-edf. This page describes version 1.15.2+etm22, published in the
stable channel.
- Adding: in an administrator session, Tariff screen → Add a provider, then the Contrat d'électricité device (the plugin's labels are in French); then choose it in Tariff source.
- Settings: the contract option; the prices, either those of the regulated tariff shipped with the package (it carries its effective date and changes only with a package update) or your own, in c€/kWh including taxes; the subscribed power in kVA (the Base price depends on it); the off-peak ranges, in the box's local time; for EJP, the number of peak days of the season already passed at installation.
- Tempo: this option is refused when adding, for now, with a message.
- EJP days: EDF publishes no calendar the box could read. Declare the peak day the day before, from the app (EJP day tomorrow); a day not declared is presumed normal.
What the box does with it, off-peak hours and peak price: see Tariffs.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: Enedis, EDF
Plugin: Edf
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Compteur Linky (TIC) | — | — | Manual | 28 |
| Contrat d'électricité | — | — | Manual / Auto-discovery | 23 |
Per-model detail¶
Compteur Linky (TIC) — linky
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
serialPort |
Port série de la TIC (/dev/serial0, /dev/ttyUSB0, ...) | QString | — | /dev/serial0 |
no |
serialMode |
Réglage du port | QString | — | 8N1, bit 7 masqué (tout port, dont le mini-UART du Raspberry Pi) |
no |
ticMode |
Mode de la TIC du compteur | QString | — | Historique (1200 bauds) |
no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Trames reçues (TIC) | bool | — |
ticMode |
Mode de la TIC | QString | — |
contractOption |
Option tarifaire lue (OPTARIF) | QString | — |
currentPeriod |
Période tarifaire en cours (PTEC, code) | QString | — |
currentPeriodLabel |
Période tarifaire en cours | QString | — |
ejpNotice |
Préavis de pointe mobile EJP (PEJP) | bool | — |
ejpNoticeMinutes |
Préavis EJP (minutes) | uint | Minutes |
tempoTomorrow |
Couleur Tempo du lendemain (DEMAIN) | QString | — |
indexBase |
Index Base (BASE) | double | KiloWattHour |
indexHc |
Index heures creuses (HCHC) | double | KiloWattHour |
indexHp |
Index heures pleines (HCHP) | double | KiloWattHour |
indexEjpHn |
Index EJP heures normales (EJPHN) | double | KiloWattHour |
indexEjpPm |
Index EJP pointe mobile (EJPHPM) | double | KiloWattHour |
indexTempoHcBlue |
Index Tempo HC jours bleus (BBRHCJB) | double | KiloWattHour |
indexTempoHpBlue |
Index Tempo HP jours bleus (BBRHPJB) | double | KiloWattHour |
indexTempoHcWhite |
Index Tempo HC jours blancs (BBRHCJW) | double | KiloWattHour |
indexTempoHpWhite |
Index Tempo HP jours blancs (BBRHPJW) | double | KiloWattHour |
indexTempoHcRed |
Index Tempo HC jours rouges (BBRHCJR) | double | KiloWattHour |
indexTempoHpRed |
Index Tempo HP jours rouges (BBRHPJR) | double | KiloWattHour |
threePhase |
Compteur triphasé | bool | — |
currentPhaseA |
Intensité instantanée phase 1 (IINST, IINST1) | double | Ampere |
currentPhaseB |
Intensité instantanée phase 2 (IINST2) | double | Ampere |
currentPhaseC |
Intensité instantanée phase 3 (IINST3) | double | Ampere |
apparentPower |
Puissance apparente (PAPP, en VA, pas en W) | double | VoltAmpere |
subscribedCurrent |
Intensité souscrite (ISOUSC) | double | Ampere |
overcurrentWarning |
Dépassement de la puissance souscrite (ADPS / ADIR) | bool | — |
badChecksums |
Groupes à somme de contrôle fausse (ignorés) | uint | — |
interruptedFrames |
Trames interrompues (ignorées) | uint | — |
Contrat d'électricité — contract
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
contractType |
Option du contrat | QString | — | Base |
no |
priceSource |
Prix | QString | — | Barème réglementé (Tarif Bleu EDF) |
no |
subscribedPower |
Puissance souscrite (kVA) | uint | — | 6 |
no |
offPeakRanges |
Plages d'heures creuses, heure locale (ex. 22:00-06:00 ou 12:00-14:00, 22:00-04:00) | QString | — | 22:00-06:00 |
no |
priceBase |
Prix saisi Base (c€/kWh TTC) | double | — | 0 |
no |
priceHc |
Prix saisi heures creuses (c€/kWh TTC) | double | — | 0 |
no |
priceHp |
Prix saisi heures pleines (c€/kWh TTC) | double | — | 0 |
no |
priceEjpHn |
Prix saisi EJP heures normales (c€/kWh TTC) | double | — | 0 |
no |
priceEjpPm |
Prix saisi EJP pointe mobile (c€/kWh TTC) | double | — | 0 |
no |
ejpPeakDaysBefore |
EJP : jours de pointe déjà passés cette saison, à l'installation (0-22, celui en cours compris) | uint | 0–22 | 0 |
no |
linkyThing |
Compteur Linky lié (identifiant, vide = aucun ; proposé par la découverte) | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
currentPeriod |
Période en cours (code) | QString | — |
currentPeriodLabel |
Période en cours | QString | — |
currentMarketPrice |
Prix en cours (c€/kWh TTC) | double | EuroCentPerKiloWattHour |
rank |
Prix nominal (0 = le moins cher du contrat, 100 = le plus cher) | uint | — |
priceKnown |
Prix en cours connu | bool | — |
currentSource |
Source de la période en cours | QString | — |
nextSwitch |
Prochaine bascule (heure locale de la box) | QString | — |
validUntil |
Prix valable jusqu'à | int | UnixTime |
tariffSource |
Origine des prix | QString | — |
regulatedTariffDate |
Date d'effet du barème réglementé fourni | QString | — |
regulatedTariffToVerify |
Barème réglementé à vérifier | bool | — |
ejpToday |
EJP aujourd'hui | QString | — |
ejpTodaySource |
EJP aujourd'hui : source | QString | — |
ejpTomorrow |
EJP demain | QString | — |
ejpTomorrowSource |
EJP demain : source | QString | — |
ejpSeasonPeakDays |
Jours de pointe EJP de la saison (saisis + vus, sur 22) | uint | — |
ejpSeasonUnknownDays |
Jours comptés par la box au statut inconnu (saison) | uint | — |
ejpSeasonComplete |
Compteur de saison complet | bool | — |
ejpSeasonCountStart |
Compteur de saison : jours comptés par la box à partir du (avant : nombre saisi) | QString | — |
discrepancy |
Écart entre la TIC et la déclaration EJP ou les plages saisies | QString | — |
subscribedPowerDiscrepancy |
Écart entre la puissance souscrite saisie et celle du compteur (ISOUSC) | QString | — |
linkyStatus |
Compteur Linky lié | QString | — |
priceSlotsTransport |
Créneaux de prix jusqu'à la fin du lendemain (transport, pas une valeur) | QVariantMap | — |