Skip to content

KOSTAL Solar Electric

STABLE NYMEA CONSUMER

Connection: LOCAL

Connect to Kostal Solar Electric inverters.

Installation guide coming soon.

Reference

Application labels

The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.

Manufacturer: KOSTAL Solar Electric
Plugin: Kostal

Supported models

Model Role Transport Pairing Quantities
KOSTAL Inverter solarinverter Modbus TCP Auto-discovery / Manual 13
KOSTAL Meter Energy meter — Automatic 14
KOSTAL Battery energystorage — Automatic 8

Per-model detail

KOSTAL Inverter — kostalInverter

Discovery parameters:

Key Label Type Range Default
port Port int — 1502
slaveId Slave ID int — 71

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — no
hostName Host name QString — — no
address IP address QString — — no
serialNumber serialNumber QString — — no
port Port int — 1502 no
slaveId Slave ID int — 71 no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
currentPower Active power double Watt
totalEnergyProduced Total energy produced double KiloWattHour
phaseACurrent Phase A current double Ampere
phaseBCurrent Phase B current double Ampere
phaseCCurrent Phase C current double Ampere
voltagePhaseA Voltage phase A double Volt
voltagePhaseB Voltage phase B double Volt
voltagePhaseC Voltage phase C double Volt
currentPowerPhaseA Current power phase A double Watt
currentPowerPhaseB Current power phase B double Watt
currentPowerPhaseC Current power phase C double Watt
frequency Frequency double Hertz
KOSTAL Meter — kostalMeter

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
currentPower Current power double Watt
totalEnergyProduced Total returned energy double KiloWattHour
totalEnergyConsumed Total imported energy double KiloWattHour
currentPhaseA Phase A current double Ampere
currentPhaseB Phase B current double Ampere
currentPhaseC Phase C current double Ampere
currentPowerPhaseA Current power phase A double Watt
currentPowerPhaseB Current power phase B double Watt
currentPowerPhaseC Current power phase C double Watt
voltagePhaseA Voltage phase A double Volt
voltagePhaseB Voltage phase B double Volt
voltagePhaseC Voltage phase C double Volt
frequency Frequency double Hertz
KOSTAL Battery — kostalBattery

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
batteryCritical Battery critical bool —
batteryLevel Battery level int Percentage
currentPower Total real power double Watt
voltage Voltage double Volt
temperature Temperature double DegreeCelsius
capacity Capacity double KiloWattHour
chargingState Charging state QString —