Skip to content

SunSpec

STABLE NYMEA CONSUMER

Connection: LOCAL

Connect to SunSpec devices.

Brand pages: SolarEdge TESTING

Installation guide coming soon.

Reference

Application labels

The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.

Manufacturer: SunSpec, SolarEdge
Plugin: SunSpec

Supported models

Model Role Transport Pairing Quantities
SunSpec Generic gateway Modbus TCP Auto-discovery / Manual 1
SunSpec single phase inverter solarinverter — Auto 13
SunSpec split phase inverter solarinverter — Auto 16
SunSpec three phase inverter solarinverter — Auto 18
SunSpec single phase meter Energy meter — Auto 8
SunSpec split phase meter Energy meter — Auto 18
SunSpec three phase meter Energy meter — Auto 21
SunSpec Storage battery — Auto 11
SolarEdge gateway Modbus TCP Auto-discovery / Manual 1
SolarEdge battery energystorage — Auto 14

Per-model detail

SunSpec Generic — sunspecConnection

Discovery parameters:

Key Label Type Range Default
slaveId Slave ID int — 1

Settings:

Key Label Type Range Default Read-only
address Host address QString — — no
hostName Host name QString — — no
macAddress MAC address QString — — no
port Port int — 502 no
slaveId Slave ID int — 1 no
endianness Endianness QString — Big Endian no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
SunSpec single phase inverter — sunspecSinglePhaseInverter

Settings:

Key Label Type Range Default Read-only
modelId Model int — — yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
totalCurrent Total AC current double Ampere
phaseVoltage Phase voltage double Volt
currentPower AC power double Watt
frequency Frequency double Hertz
totalEnergyProduced AC energy double KiloWattHour
voltageDc DC voltage double Volt
currentDc DC current double Ampere
currentPowerDc DC power double Watt
cabinetTemperature Cabinet temperature double DegreeCelsius
operatingState Operating state QString —
error Error QString —
version Version QString —
SunSpec split phase inverter — sunspecSplitPhaseInverter

Settings:

Key Label Type Range Default Read-only
modelId Model int — — yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
totalCurrent Total AC current double Ampere
phaseACurrent Phase A current double Ampere
phaseBCurrent Phase B current double Ampere
phaseANVoltage Phase AN voltage double Volt
phaseBNVoltage Phase BN voltage double Volt
currentPower AC power double Watt
frequency Line frequency double Hertz
totalEnergyProduced AC energy double KiloWattHour
voltageDc DC voltage double Volt
currentDc DC current double Ampere
currentPowerDc DC power double Watt
cabinetTemperature Cabinet temperature double DegreeCelsius
operatingState Operating state QString —
error Error QString —
version Version QString —
SunSpec three phase inverter — sunspecThreePhaseInverter

Settings:

Key Label Type Range Default Read-only
modelId Model int — — yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
totalCurrent Total AC current double Ampere
phaseACurrent Phase A current double Ampere
phaseBCurrent Phase B current double Ampere
phaseCCurrent Phase C current double Ampere
phaseANVoltage Phase AN voltage double Volt
phaseBNVoltage Phase BN voltage double Volt
phaseCNVoltage Phase CN voltage int Volt
currentPower AC power double Watt
frequency Frequency double Hertz
totalEnergyProduced AC energy double KiloWattHour
voltageDc DC voltage double Volt
currentDc DC current double Ampere
currentPowerDc DC power double Watt
cabinetTemperature Cabinet temperature double DegreeCelsius
operatingState Operating state QString —
error Error QString —
version Version QString —
SunSpec single phase meter — sunspecSinglePhaseMeter

Settings:

Key Label Type Range Default Read-only
modelId Model int — 0 yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
currentPower Total real power double Watt
totalEnergyProduced Total real energy exported double KiloWattHour
totalEnergyConsumed Total real energy imported double KiloWattHour
currentPhaseA Phase A current double Ampere
voltagePhaseA Phase A voltage double Volt
frequency Frequency double Hertz
version Version QString —
SunSpec split phase meter — sunspecSplitPhaseMeter

Settings:

Key Label Type Range Default Read-only
modelId Model int — 0 yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
totalEnergyProduced Total real energy exported double KiloWattHour
totalEnergyConsumed Total real energy imported double KiloWattHour
currentPower Total real power double Watt
energyConsumedPhaseA Energy consumed phase A double KiloWattHour
energyConsumedPhaseB Energy consumed phase B double KiloWattHour
energyProducedPhaseA Energy produced phase A double KiloWattHour
energyProducedPhaseB Energy produced phase B double KiloWattHour
totalCurrent Total AC current double Ampere
currentPowerPhaseA Current power phase A double Watt
currentPowerPhaseB Current power phase B double Watt
currentPhaseA Phase A current double Ampere
currentPhaseB Phase B current double Ampere
lnACVoltage Line to Neutral AC Voltage double Volt
voltagePhaseA Phase A voltage double Volt
voltagePhaseB Phase B voltage double Volt
frequency Frequency double Hertz
version Version QString —
SunSpec three phase meter — sunspecThreePhaseMeter

Settings:

Key Label Type Range Default Read-only
modelId Model int — 0 yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
totalEnergyProduced Total real energy exported double KiloWattHour
totalEnergyConsumed Total real energy imported double KiloWattHour
currentPower Total real power double Watt
energyConsumedPhaseA Energy consumed phase A double KiloWattHour
energyConsumedPhaseB Energy consumed phase B double KiloWattHour
energyConsumedPhaseC Energy consumed phase C double KiloWattHour
energyProducedPhaseA Energy produced phase A double KiloWattHour
energyProducedPhaseB Energy produced phase B double KiloWattHour
energyProducedPhaseC Energy produced phase C double KiloWattHour
currentPowerPhaseA Current power phase A double Watt
currentPowerPhaseB Current power phase B double Watt
currentPowerPhaseC Current power phase C double Watt
currentPhaseA Phase A current double Ampere
currentPhaseB Phase B current double Ampere
currentPhaseC Phase C current double Ampere
voltagePhaseA Phase A voltage double Volt
voltagePhaseB Phase B voltage double Volt
voltagePhaseC Phase C voltage double Volt
frequency Frequency double Hertz
version Version QString —
SunSpec Storage — sunspecStorage

Settings:

Key Label Type Range Default Read-only
modelId Model int — 0 yes
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — Unkown no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
batteryCritical Battery critical bool —
batteryLevel Battery level int Percentage
storageStatus Status QString —
chargingState Charging state QString —
gridCharging Grid charging bool —
enableCharging Charging bool —
enableDischarging Discharging bool —
chargingRate Charging rate int Percentage
dischargingRate Discharging rate int Percentage
version Version QString —
SolarEdge — solarEdgeConnection

Discovery parameters:

Key Label Type Range Default
slaveId Slave ID int — 1

Settings:

Key Label Type Range Default Read-only
address Host address QString — — no
hostName Host name QString — — no
macAddress MAC address QString — — no
port Port int — 502 no
slaveId Slave ID int — 1 no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
SolarEdge battery — solarEdgeBattery

Settings:

Key Label Type Range Default Read-only
modbusAddress Modbus address uint — 0 yes
manufacturer Manufacturer QString — Unkown no
deviceModel Device model QString — Unkown no
serialNumber Serial number QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
batteryCritical Battery critical bool —
batteryLevel Battery level int Percentage
chargingState Charging state QString —
ratedEnergy Rated energy double KiloWattHour
averageTemperature Average temperature double DegreeCelsius
instantaneousVoltage Instantaneous voltage double Volt
instantaneousCurrent Instantaneous current double Ampere
currentPower Instantaneous power double Watt
maxEnergy Maximum energy double KiloWattHour
capacity Available energy double KiloWattHour
stateOfHealth State of health (SOH) double Percentage
batteryStatus Battery status QString —
version Version QString —