Skip to content

V2C Trydan

STABLE ETM CONSUMER

Connection: LOCAL

Control the V2C Trydan charger locally, over its HTTP API.

The V2C Trydan charger is controlled locally, over its HTTP API, with no account and nothing going through the internet. The plugin is powersync-plugin-v2c, installed with powersync-core through the powersync-plugins-supported meta-package: nothing else to install.

  • Charger port: 80.
  • Commands: pause and resume, charging current.
  • Measurements: power, current and voltage per phase, session energy.
  • Model in the app: Trydan (HTTP).

Charger added with the Modbus plugin

The Modbus TCP plugin (powersync-plugin-modbus-v2c) is no longer published nor maintained. A charger added with that plugin is added with the HTTP plugin, with the charger's local API enabled: remove the device added over Modbus, then add the charger with the Trydan (HTTP) model.

Over the HTTP API, every command is read back from the charger: it succeeds only if the charger reports the written value. A setpoint below the charger's minimum current (6 A) does not set it to the minimum, which would draw more than asked: it pauses the charge.

One controller per charger

Do not control the charger alongside another energy manager: two controllers fight over the setpoint.

Before adding it

  • The charger is on the local network, with a fixed IPv4 address (DHCP reservation), and its local HTTP API is enabled.
  • The box suspends the charger's own power control (Dynamic) as long as the setting Suspend the charger's own power control (PauseDynamic) allows it; it is on by default.

Wiring: chosen by the installer

The charger does not report how it is wired. The installer chooses it when adding the charger, in the wiring parameter (Wiring of this Trydan (installer: single-phase or three-phase model and supply)), with no default:

Value Wiring
Three phase - 3 x 400 V, up to 22 kW three-phase charger
Single phase - 1 x 230 V, up to 7.4 kW single-phase charger, on L1
Choose the wiring none: adding is refused

Single-phase charger: on phase L1

A single-phase Trydan is connected on phase L1: the engine counts its draw on that phase to protect the subscribed power phase by phase.

A change of wiring is entered by reconfiguring the charger. When the charger reports the voltage of each phase, the plugin compares the chosen wiring with the voltage measured on L2 and L3 and publishes the result in wiringCheck, for information.

In the app

  • Adding: in an administrator session, Add a device, the model, then Discover devices, see The app.
  • Charging modes: Auto (sun first, off-peak hours next) and Manuel (manual), with the Charge switch: on, full power; off, charger stopped. When unplugged, the charger goes back to Auto by itself. See Solar surplus.
  • Reason: every decision of the engine on the charger is shown with its reason, see The reason for every decision.

Reference

Application labels

The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.

Manufacturer: V2C
Plugin: Trydan

Supported models

Model Role Transport Pairing Quantities
Trydan (HTTP) EV charger, Consumption meter HTTP Auto-discovery / Manual 25

Per-model detail

Trydan (HTTP) — trydan

Settings:

Key Label Type Range Default Read-only
address IP address QString — — no
wiring Wiring of this Trydan (installer: single-phase or three-phase model and supply) QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
charging Charging bool —
power Charging enabled bool —
maxChargingCurrent Maximum charging current double Ampere
currentPower Charging power double Watt
totalEnergyConsumed Total energy consumed double KiloWattHour
sessionEnergy Session energy double KiloWattHour
chargeEnergy Charge energy (raw charger counter) double KiloWattHour
currentPhaseA Current phase A double Ampere
currentPhaseB Current phase B double Ampere
currentPhaseC Current phase C double Ampere
voltagePhaseA Voltage phase A double Volt
voltagePhaseB Voltage phase B double Volt
voltagePhaseC Voltage phase C double Volt
phaseMeasurementsAvailable Per-phase measurements available bool —
phaseCount Phases in use uint —
desiredPhaseCount Desired number of charging phases uint —
chargeMode Phase mode of the charger QString —
wiringCheck Wiring check (voltages on L2/L3) QString —
locked Locked on the charger bool —
internalOptimizerActive Charger's own power control configured (Dynamic) bool —
optimizerSuspended Charger's own power control suspended (PauseDynamic) bool —
slaveError Charger error code uint —
firmwareVersion Firmware version QString —