V2C Trydan¶
STABLE ETM CONSUMER
Connection: LOCAL
Control the V2C Trydan charger locally, over its HTTP API.
The V2C Trydan charger is controlled locally, over its HTTP API, with no account and
nothing going through the internet. The plugin is powersync-plugin-v2c, installed with
powersync-core through the powersync-plugins-supported meta-package: nothing else to install.
- Charger port: 80.
- Commands: pause and resume, charging current.
- Measurements: power, current and voltage per phase, session energy.
- Model in the app:
Trydan (HTTP).
Charger added with the Modbus plugin
The Modbus TCP plugin (powersync-plugin-modbus-v2c) is no longer published nor maintained.
A charger added with that plugin is added with the HTTP plugin, with the charger's local API
enabled: remove the device added over Modbus, then add the charger with the Trydan (HTTP)
model.
Over the HTTP API, every command is read back from the charger: it succeeds only if the charger reports the written value. A setpoint below the charger's minimum current (6 A) does not set it to the minimum, which would draw more than asked: it pauses the charge.
One controller per charger
Do not control the charger alongside another energy manager: two controllers fight over the setpoint.
Before adding it¶
- The charger is on the local network, with a fixed IPv4 address (DHCP reservation), and its local HTTP API is enabled.
- The box suspends the charger's own power control (
Dynamic) as long as the settingSuspend the charger's own power control (PauseDynamic)allows it; it is on by default.
Wiring: chosen by the installer¶
The charger does not report how it is wired. The installer chooses it when adding the charger,
in the wiring parameter
(Wiring of this Trydan (installer: single-phase or three-phase model and supply)), with no
default:
| Value | Wiring |
|---|---|
Three phase - 3 x 400 V, up to 22 kW |
three-phase charger |
Single phase - 1 x 230 V, up to 7.4 kW |
single-phase charger, on L1 |
Choose the wiring |
none: adding is refused |
Single-phase charger: on phase L1
A single-phase Trydan is connected on phase L1: the engine counts its draw on that phase to protect the subscribed power phase by phase.
A change of wiring is entered by reconfiguring the charger. When the charger reports the voltage
of each phase, the plugin compares the chosen wiring with the voltage measured on L2 and L3 and
publishes the result in wiringCheck, for information.
In the app¶
- Adding: in an administrator session, Add a device, the model, then Discover devices, see The app.
- Charging modes: Auto (sun first, off-peak hours next) and Manuel (manual), with the Charge switch: on, full power; off, charger stopped. When unplugged, the charger goes back to Auto by itself. See Solar surplus.
- Reason: every decision of the engine on the charger is shown with its reason, see The reason for every decision.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: V2C
Plugin: Trydan
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Trydan (HTTP) | EV charger, Consumption meter | HTTP | Auto-discovery / Manual | 25 |
Per-model detail¶
Trydan (HTTP) — trydan
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
address |
IP address | QString | — | — | no |
wiring |
Wiring of this Trydan (installer: single-phase or three-phase model and supply) | QString | — | — | no |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Connected | bool | — |
pluggedIn |
Plugged in | bool | — |
charging |
Charging | bool | — |
power |
Charging enabled | bool | — |
maxChargingCurrent |
Maximum charging current | double | Ampere |
currentPower |
Charging power | double | Watt |
totalEnergyConsumed |
Total energy consumed | double | KiloWattHour |
sessionEnergy |
Session energy | double | KiloWattHour |
chargeEnergy |
Charge energy (raw charger counter) | double | KiloWattHour |
currentPhaseA |
Current phase A | double | Ampere |
currentPhaseB |
Current phase B | double | Ampere |
currentPhaseC |
Current phase C | double | Ampere |
voltagePhaseA |
Voltage phase A | double | Volt |
voltagePhaseB |
Voltage phase B | double | Volt |
voltagePhaseC |
Voltage phase C | double | Volt |
phaseMeasurementsAvailable |
Per-phase measurements available | bool | — |
phaseCount |
Phases in use | uint | — |
desiredPhaseCount |
Desired number of charging phases | uint | — |
chargeMode |
Phase mode of the charger | QString | — |
wiringCheck |
Wiring check (voltages on L2/L3) | QString | — |
locked |
Locked on the charger | bool | — |
internalOptimizerActive |
Charger's own power control configured (Dynamic) | bool | — |
optimizerSuspended |
Charger's own power control suspended (PauseDynamic) | bool | — |
slaveError |
Charger error code | uint | — |
firmwareVersion |
Firmware version | QString | — |