Skip to content

PhoenixConnect

STABLE NYMEA CONSUMER

Connection: LOCAL

Control and monitor Wallbe, Compleo and Scapo wallboxes.

Installation guide coming soon.

Reference

Application labels

The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.

Manufacturer: Wallbe, compleo, scapo
Plugin: PhoenixConnect

Supported models

Model Role Transport Pairing Quantities
Wallbe ECO 2.0 evchargerac Modbus TCP Auto-discovery / Manual 8
Wallbe Pro evchargerac, Consumption meter Modbus TCP Auto-discovery / Manual 10
Compleo ECO s evchargerac Modbus TCP Auto-discovery / Manual 8
Compleo PRO evchargerac, Consumption meter Modbus TCP Auto-discovery / Manual 10
Compleo eBOX professional evchargerac Modbus TCP Auto-discovery / Manual 7
Scapo Economy evchargerac Modbus TCP Auto-discovery / Manual 8
Scapo Vision evchargerac, Consumption meter Modbus TCP Auto-discovery / Manual 9

Per-model detail

Wallbe ECO 2.0 — wallbeEco2

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
chargeTime Charging Time int Minutes
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
phaseCount Phase count uint —
Wallbe Pro — wallbePro

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
chargeTime Charging Time int Minutes
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
totalEnergyConsumed Total consumed energy double KiloWattHour
currentPower Current power usage double Watt
phaseCount Phase count uint —
Compleo ECO s — compleoEcoS

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
chargeTime Charging Time int Minutes
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
phaseCount Phase count uint —
Compleo PRO — compleoPro

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
chargeTime Charging Time int Minutes
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
totalEnergyConsumed Total consumed energy double KiloWattHour
currentPower Current power usage double Watt
phaseCount Phase count uint —
Compleo eBOX professional — compleoEBoxProfessional

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no
port Modbus TCP port uint 1–65535 502 no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
phaseCount Phase count uint —
Scapo Economy — scapoEco

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
chargeTime Charging Time int Minutes
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
phaseCount Phase count uint —
Scapo Vision — scapoVision

Settings:

Key Label Type Range Default Read-only
macAddress MAC address QString — — yes
address Host address QString — — no
hostName Host name QString — — no

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
pluggedIn Plugged in bool —
power Charging enabled bool —
charging Charging bool —
maxChargingCurrent Charging current double Ampere
firmwareVersion Firmware version QString —
totalEnergyConsumed Total consumed energy double KiloWattHour
currentPower Current power usage double Watt
phaseCount Phase count uint —