Fronius¶
STABLE NYMEA CONSUMER
Connection: LOCAL
Connect to Fronius Solar devices.
Installation guide coming soon.
Reference¶
Application labels
The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.
Manufacturer: Fronius
Plugin: fronius
Supported models¶
| Model | Role | Transport | Pairing | Quantities |
|---|---|---|---|---|
| Fronius Solar | gateway | Modbus TCP | Auto-discovery / Manual | 2 |
| Fronius solar inverter | solarinverter | — | Automatic | 5 |
| Fronius smart meter | Energy meter | — | Automatic | 14 |
| Fronius solar storage | energystorage | — | Automatic | 7 |
Per-model detail¶
Fronius Solar — connection
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
address |
Host address | QString | — | — | no |
hostName |
Host name | QString | — | — | no |
macAddress |
Mac address | QString | — | 00:00:00:00:00:00 |
yes |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Reachable | bool | — |
version |
Version | QString | — |
Fronius solar inverter — inverter
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
id |
Device ID | QString | — | — | yes |
serialNumber |
Serial number | QString | — | — | yes |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Reachable | bool | — |
currentPower |
Current power | double | Watt |
energyDay |
Energy produced today | double | KiloWattHour |
energyYear |
Energy produced year | int | KiloWattHour |
totalEnergyProduced |
Total produced energy | double | KiloWattHour |
Fronius smart meter — meter
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
id |
Device ID | QString | — | — | yes |
serialNumber |
Serial number | QString | — | — | yes |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Reachable | bool | — |
currentPower |
Current power usage | double | Watt |
voltagePhaseA |
Voltage phase A | double | Volt |
voltagePhaseB |
Voltage phase B | double | Volt |
voltagePhaseC |
Voltage phase C | double | Volt |
currentPhaseA |
Current phase A | double | Ampere |
currentPhaseB |
Current phase B | double | Ampere |
currentPhaseC |
Current phase C | double | Ampere |
totalEnergyProduced |
Energy produced | double | KiloWattHour |
totalEnergyConsumed |
Energy Consumed | double | KiloWattHour |
currentPowerPhaseA |
Current power phase A | double | Watt |
currentPowerPhaseB |
Current power phase B | double | Watt |
currentPowerPhaseC |
Current power phase C | double | Watt |
frequency |
Frequency | double | Hertz |
Fronius solar storage — storage
Settings:
| Key | Label | Type | Range | Default | Read-only |
|---|---|---|---|---|---|
id |
Device ID | QString | — | — | yes |
serialNumber |
Serial number | QString | — | — | yes |
Measured quantities:
| Key | Quantity | Type | Unit |
|---|---|---|---|
connected |
Reachable | bool | — |
chargingState |
Charging state | QString | — |
currentPower |
Current power | double | Watt |
capacity |
Capacity | double | KiloWattHour |
batteryLevel |
Battery level | int | Percentage |
cellTemperature |
Cell temperature | double | DegreeCelsius |
batteryCritical |
Battery level critical | bool | — |