Skip to content

SMA

STABLE NYMEA CONSUMER

Connection: LOCAL

Connect to SMA solar equipment.

Installation guide coming soon.

Reference

Application labels

The keys and labels below are the ones the application shows, in English. They are left verbatim so that you find them word for word on screen.

Manufacturer: SMA Solar Technology AG
Plugin: sma

Supported models

Model Role Transport Pairing Quantities
SMA Sunny WebBox solarinverter Modbus TCP Auto-discovery / Manual 6
SMA Energy Meter Energy meter — Auto-discovery / Manual 20
SMA Inverter solarinverter Modbus TCP Auto-discovery / Manual 14
SMA Battery energystorage — Automatic 9
SMA Solar Inverter (Modbus) solarinverter Modbus TCP Auto-discovery / Manual 14
SMA Battery Inverter (Modbus) energystorage Modbus TCP Auto-discovery / Manual 7

Per-model detail

SMA Sunny WebBox — sunnyWebBox

Settings:

Key Label Type Range Default Read-only
address Host address QString — — no
hostName Host name QString — — no
macAddress MAC address QString — — yes

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
currentPower Current power double Watt
dayEnergyProduced Day energy produced double KiloWattHour
totalEnergyProduced Total energy produced double KiloWattHour
mode Mode QString —
error Error QString —
SMA Energy Meter — speedwireMeter

Settings:

Key Label Type Range Default Read-only
serialNumber Serial number QString — — yes
modelId Model ID uint — — yes

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
voltagePhaseA Voltage phase A double Volt
voltagePhaseB Voltage phase B double Volt
voltagePhaseC Voltage phase C double Volt
currentPhaseA Current phase A double Ampere
currentPhaseB Current phase B double Ampere
currentPhaseC Current phase C double Ampere
currentPower Current power double Watt
currentPowerPhaseA Current power phase A double Watt
currentPowerPhaseB Current power phase B double Watt
currentPowerPhaseC Current power phase C double Watt
totalEnergyConsumed Total energy consumed double KiloWattHour
totalEnergyProduced Total energy produced double KiloWattHour
energyConsumedPhaseA Energy consumed phase A double KiloWattHour
energyConsumedPhaseB Energy consumed phase B double KiloWattHour
energyConsumedPhaseC Energy consumed phase C double KiloWattHour
energyProducedPhaseA Energy produced phase A double KiloWattHour
energyProducedPhaseB Energy produced phase B double KiloWattHour
energyProducedPhaseC Energy produced phase C double KiloWattHour
firmwareVersion Firmware version QString —
SMA Inverter — speedwireInverter

Settings:

Key Label Type Range Default Read-only
address Host address QString — — no
hostName Host name QString — — no
macAddress MAC address QString — — yes
serialNumber Serial number QString — — yes
modelId Model ID uint — 0 yes

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
voltagePhaseA Voltage phase A double Volt
voltagePhaseB Voltage phase B double Volt
voltagePhaseC Voltage phase C double Volt
currentPhaseA Current phase A double Ampere
currentPhaseB Current phase B double Ampere
currentPhaseC Current phase C double Ampere
currentPower Current power double Watt
currentPowerMpp1 DC power MPP1 double Watt
currentPowerMpp2 DC power MPP2 double Watt
totalEnergyProduced Total energy produced double KiloWattHour
energyProducedToday Energy produced today double KiloWattHour
frequency Frequency double Hertz
firmwareVersion Firmware version QString —
SMA Battery — speedwireBattery

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
voltage Voltage double Volt
current Current double Ampere
temperature Temperature double DegreeCelsius
currentPower Current power double Watt
capacity Available energy double KiloWattHour
batteryCritical Battery critical bool —
batteryLevel Battery level int Percentage
chargingState Charging state QString —
SMA Solar Inverter (Modbus) — modbusSolarInverter

Settings:

Key Label Type Range Default Read-only
address Host address QString — — no
hostName Host name QString — — no
macAddress MAC address QString — — no
port Port int — 502 no
slaveId Slave ID int — 3 no
serialNumber Serial number QString — — yes

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
voltagePhaseA Voltage phase A double Volt
voltagePhaseB Voltage phase B double Volt
voltagePhaseC Voltage phase C double Volt
currentPhaseA Current phase A double Ampere
currentPhaseB Current phase B double Ampere
currentPhaseC Current phase C double Ampere
currentPower Current power double Watt
currentPowerPhaseA Current power phase A double Watt
currentPowerPhaseB Current power phase B double Watt
currentPowerPhaseC Current power phase C double Watt
totalEnergyProduced Total energy produced double KiloWattHour
energyProducedToday Energy produced today double KiloWattHour
firmwareVersion Firmware version QString —
SMA Battery Inverter (Modbus) — modbusBatteryInverter

Settings:

Key Label Type Range Default Read-only
address Host address QString — — no
hostName Host name QString — — no
macAddress MAC address QString — — no
port Port int — 502 no
slaveId Slave ID int — 3 no
serialNumber Serial number QString — — yes

Measured quantities:

Key Quantity Type Unit
connected Connected bool —
batteryLevel Battery level int Percentage
batteryCritical Battery critical bool —
currentPower Current power double Watt
capacity Capacity double KiloWattHour
chargingState Charging state QString —
firmwareVersion Firmware version QString —