Wattsonic¶
NIGHTLY NYMEA CONSUMER
Connect Wattsonic devices to nymea.
Fabricant : Wattsonic
Plugin : Wattsonic
Modèles pris en charge¶
| Modèle | Rôle | Transport | Ajout | Grandeurs |
|---|---|---|---|---|
| Wattsonic hybrid inverter | solarinverter | Modbus RTU | Découverte automatique / Ajout manuel | 3 |
| Wattsonic energy meter | Compteur d'énergie | — | Automatique | 13 |
| Wattsonic energy storage | energystorage | — | Automatique | 6 |
Détail par modèle¶
Wattsonic hybrid inverter — inverter
Paramètres de découverte :
| Clé | Libellé | Type | Plage | Défaut |
|---|---|---|---|---|
slaveAddress |
Modbus slave address | uint | — | 247 |
Réglages :
| Clé | Libellé | Type | Plage | Défaut | Lecture seule |
|---|---|---|---|---|---|
slaveAddress |
Modbus slave address | uint | — | 247 |
non |
modbusMasterUuid |
Modbus RTU master | QUuid | — | — | non |
serialNumber |
Serial number | QString | — | — | non |
inverterGeneration |
Inverter generation | QString | — | Auto |
non |
Grandeurs mesurées :
| Clé | Grandeur | Type | Unité |
|---|---|---|---|
connected |
Connected | bool | — |
totalEnergyProduced |
Total energy produced | double | KiloWattHour |
currentPower |
Current power consumption | double | Watt |
Wattsonic energy meter — meter
Grandeurs mesurées :
| Clé | Grandeur | Type | Unité |
|---|---|---|---|
connected |
Connected | bool | — |
currentPower |
Current power consumption | double | Watt |
totalEnergyConsumed |
Total consumed energy | double | KiloWattHour |
totalEnergyProduced |
Total returned energy | double | KiloWattHour |
currentPowerPhaseA |
Power consumption phase A | double | Watt |
currentPowerPhaseB |
Power consumption phase B | double | Watt |
currentPowerPhaseC |
Power consumption phase C | double | Watt |
voltagePhaseA |
Voltage phase A | double | Volt |
voltagePhaseB |
Voltage phase B | double | Volt |
voltagePhaseC |
Voltage phase C | double | Volt |
currentPhaseA |
Current phase A | double | Ampere |
currentPhaseB |
Current phase B | double | Ampere |
currentPhaseC |
Current phase C | double | Ampere |
Wattsonic energy storage — battery
Grandeurs mesurées :
| Clé | Grandeur | Type | Unité |
|---|---|---|---|
connected |
Connected | bool | — |
batteryCritical |
Battery critical | bool | — |
batteryLevel |
Battery level | int | Percentage |
chargingState |
Charging state | QString | — |
currentPower |
Current power consumption | double | Watt |
capacity |
Capacity | double | KiloWattHour |